Konform AR Acrylic Conformal Coating

UL-certified acrylic conformal coating for insulation against high voltage arcing and shorts

Konform AR is ideal for providing insulation against high-voltage arcing and corona shorts. This extremely effective acrylic conformal coating provides a hard, durable protective barrier against humidity, salt, corrosive vapors and fungus for printed circuit board and electronic assemblies. 

CLICK HERE FOR CONFORMAL COATING SELECTION GUIDE

Features & Benefits

  • Acrylic coating working temperature from -75°F/-59°C to 279°F/137°C
  • High dielectric strength of 8300 volts/mil
  • Passes the laboratory tests of MIL-I-46058C. However, it is not qualified on QPL-46058.
  • Compliant to IPC-CC-830A
  • RoHS Compliant
  • Provides excellent acid resistance
  • Will not discolor over time under normal use
  • Easily repairable
  • Contains a UV indicator for thorough Quality Control inspection
  • UL Recognized, File E76307

Applications

  • Extends component life by protecting against adverse environments
  • Resists moisture, salt, fungus, corrosive vapors, and severe environments
  • Designed to provide effective insulation against electrical shorts and harsh environments

Swipe to View Add to Cart Button 

Part # Size Units Per Case Price Per Case Add To Cart
CTAR-12

11.5 oz. (429 ml) aerosol

12 cans $453.48
CTAR-1

1 gal / 3.7 L container

1 container $339.58
Order from an authorized distributor

FAQ's

How do you measure the thickness of conformal coating?

Measuring the thickness of conformal coating is essential to ensure proper application and adherence to the specified requirements. There are several methods used to measure the thickness, and the choice of method may depend on the type of conformal coating and the level of accuracy required. Here are some common methods:

  • Calibrated Thickness Gauges: These are handheld devices that use non-destructive methods to measure the thickness of the coating. They typically use magnetic induction or eddy current principles to determine the distance between the probe and the substrate, which correlates to the coating thickness.
  • Cross-Sectioning and Imaging: This method involves cutting a sample of the coated surface and examining it under a microscope. The thickness can be determined by measuring the height of the coating in the cross-sectional view.
  • Ultrasonic Testing: Ultrasonic thickness gauges use sound waves to measure the thickness of the coating. The device emits ultrasonic pulses, and the time taken for the waves to bounce back from the substrate-coating interface is used to calculate the thickness.
  • X-ray Fluorescence (XRF): XRF can be used to measure the thickness of conformal coatings. It involves analyzing the intensity of X-rays emitted from the coating material due to bombardment by X-rays. The thickness is determined based on the X-ray penetration depth.
  • Electrical Capacitance Method: This method utilizes the change in capacitance between electrodes positioned on opposite sides of the coated surface. The coating's thickness affects the capacitance, allowing for indirect measurement.
  • Weight Difference Method: For some applications, the thickness can be estimated by measuring the weight difference of a substrate before and after coating. This method is more suitable for thicker coatings.

Before choosing a specific method, it is important to consider factors like the type of coating material, the size and shape of the substrate, the required measurement accuracy, and whether destructive or non-destructive testing is acceptable for your specific application. Additionally, it is essential to calibrate the measurement equipment and follow any manufacturer's guidelines for accurate and reliable results.

Does your conformal coating meet MIL-I-46058C?

IPC-CC-830 is an industry standard focused on conformal coatings for printed wiring assemblies, while MIL-I-46058 was a military specification for electrical insulating compounds used on printed circuit assemblies, which has since been replaced by more comprehensive standards like MIL-STD-883 or adopted industry standards like IPC-CC-830. 

Does your conformal coating meet IPC-CC-830?

Yes, all our coatings meet IPC-CC-830 standards. IPC-CC-830 defines the requirements for electrical insulating compounds, commonly known as conformal coatings, used to protect printed circuit boards and electronic assemblies from environmental factors such as moisture, dust, chemicals, and temperature extremes. The standard outlines the testing methods and performance criteria for these insulating compounds to meet industry requirements. It includes specifications for material properties, application procedures, and performance testing for conformal coatings. You might see IPC-CC-830B, 830C, etc. The extra letter refers to the revision. The changes between revisions general do not affect all types of coatings, so coatings are often not retested to the latest standard.

How do you apply conformal coating to a printer circuit board (PCB)?

  1. Prepare the PCB: Ensure the PCB is clean, dry, and free from any contaminants. Clean it using an appropriate PCB cleaning solution or isopropyl alcohol to remove any dirt, flux residues, or other impurities that could interfere with the coating adhesion.
  2. Select the Conformal Coating: There are various types of conformal coatings available, such as acrylic (AR), silicone (SR), and urethane (UR). Choose a coating that suits your specific application and environmental conditions.
  3. Choose the Application Method: Conformal coatings can be applied using different methods, including spraying, dipping, brushing, or dispensing. The method you choose depends on the type of coating and your equipment's capabilities.
  4. Spraying: Suitable for large-scale production. It requires a specialized spray booth and spray gun to evenly apply the coating.
  5. Dipping: Involves immersing the entire PCB into a reservoir of conformal coating. This method provides uniform coverage but may trap air bubbles.
  6. Brushing: Manual application using a brush is suitable for small-scale production or touch-ups.
  7. Masking Uncoated Areas (optional): If certain components or areas on the PCB should remain uncoated (e.g., connectors, switches, or heat sinks), use a masking material (e.g., Kapton tape or liquid latex) to protect those areas during the coating process.
  8. Dispensing: Applying the coating using a controlled dispensing system, which is useful for selective coating on specific areas. Make sure to apply a thin and even layer, avoiding excessive buildup, which could lead to uneven coating thickness or encapsulation of sensitive components.
  9. Curing and Drying: Allow the applied conformal coating to cure and dry as per the manufacturer's instructions. This typically involves leaving the coated PCB in a controlled environment, such as an oven, for the recommended duration.
  10. Post-Coating Inspection: After the coating has cured, inspect the PCB to ensure proper coverage and to check for any defects, such as bubbles, pinholes, or insufficient coating.

Does conformal coating protect against ESD (static)?

While conformal coatings can offer some level of protection against ESD by providing a barrier between the sensitive electronic components and the surrounding environment, they are not specifically designed as ESD control measures.

What is the difference between full cure and tack-free cure?

Full cure is when it meets all the final specifications. There might be some out-gassing, but it will be as hard as it is going to be, and adhesion is as good as it gets.  Tack-free is as the name suggests, not sticky so you can move it along the assembly process.

How can you reduce chemical exposure?

Every organization using hazardous chemicals within their facility has the responsibility to equip their facility and personnel to maintain exposure levels below the TLV. Personal monitoring badges can be used to measure exposure of a specific material. Then, depending on the threshold limit and the application, exposure can be controlled with PPE like masks, face shields, respirators, and even coveralls. If they don’t reduce exposure below the recommended limit, you will need to consider a special ventilation hood or even containment booth. As you can see, as the exposure limit gets down to a certain level, the equipment required to safely use the solvent can get impractical. At that point, your best option is to consider a safer alternative.

What is the difference between dielectric strength and dielectric withstand voltage?

The dielectric strength is material intrinsic property and withstand voltage is surface property which depend on thickness of the material. They can be slightly different for thicker materials, but for conformal coating, the two numbers should be very close or the same. That is because we test coating at 3-5 mils thickness, calculate, then report the value per mil.

What type of UV light / black light should I use for QC inspection of the final conformal coating?

Conformal coating with UV tracer can be inspected with any typical UV lamp which has wavelength of 320-380 nm.

What solvent can I use to thin this conformal coating?

Toluene can be used as a thinning agent. Make sure it is anhydrous, so contains as little moisture as possible.

How do you apply liquid conformal coating? (CTAR)

Apply to clean, moisture-free surface.  Areas not requiring coating should be masked. Application: Coating may be applied by spraying, brushing, dipping or flow coating.  Allow coating to flow around components. Cure:  Room temperature cure: A 1.0 mil coating will be tack-free in 30 minutes.  Full cure requires 24 hours @ 77˚F (25˚C). Heat cure: 8 hours @ 170˚F (77˚C). An open vessel of water placed in the drying chamber will facilitate curing. UV detectable for QC inspection. Removal:  Coating may be removed by soaking in Electro-Wash® Two Step Cleaner Degreaser. Use CircuitWorks® Conformal Coating Remover Pen for spot removal. After the new component is installed, areas should be cleaned and recoated.

How do you use an aerosol conformal coating? (CTAR-12)

Shake well. SURFACE MUST BE CLEAN & MOISTURE FREE. Areas not requiring coating should be masked. Coating:  Spray top to bottom, allowing coating to flow around components. Rotate board 90˚ and repeat process 2 or more times.  If nozzle clogs, clean with solvent or use new nozzle. Cure:  A 1.0 mil coating will be tack-free in 30 minutes.  Full cure requires 24 hours @77˚F/25˚C. Heat Cure: 8 hours @170˚F/77˚C. An open vessel of water placed in the drying chamber will facilitate curing. UV detectable for QC inspection. Removal: Coating may be removed by soaking in Electro-Wash® Two Step. Use CircuitWorks® Conformal Coating Remover Pen for spot removal. After the new component is installed, areas should be cleaned and re-coated.

When using conformal coatings in general, what causes a "milky" cure or white "foam" on the substrate?

In almost all cases, the cloudy or milky cure comes from coating in higher humidity conditions. The white foam (from an aerosol) is caused the same way. We have the following suggestions:

  1. If possible, allow the substrate and coating material to come to approximately the same temperature when applying.
  2. Avoid applications in RH > 60%. High humidity ranges will discolor some coating resins and will start curing others. Besides the aesthetic value, it certainly may affect adhesion to the material.
  3. Specifically on the silicone coating, if the resulting application is foamy, increase the focal point of the can, ie back off to about 10 -12” from the substrate & make 2 -3 light passes rather than one heavy pass to coat the board.

What types of coverage areas are to be expected with the conformal coatings in general?

Wet film thickness = Sq. ft. per gal.

0.1 mil = 16,040

0.5 mil = 3,210

1 mil = 1,600

2 mil = 802

3 mil = 535

4 mil = 401

5 mil = 321

6 mil = 267

7 mil = 229

8 mil = 201

9 mil = 178

10 mil = 160

What spigot or spout do you recommend for your metal 5-gallon and 55-gallon drums?

Metal 5-gallon containers come with a flexible pop-out spout for easy pouring. 55-gallon drums are compatible with standard 2" spouts.

How do I properly dispose of an aerosol can after it is empty?

It may be different state-by-state, so contact your state environmental agency for regional specific regulations. For a general guideline, here is the process according to EPA hazardous waste regulations 40CFR. The can has to be brought to or approach atmospheric pressure to render the can empty. Puncturing is not required, only that it “approach atmospheric pressure”, i.e. empty the can contents until it’s no longer pressurized. This insures that as much contents as is reasonably possible are out of the can. It is then considered “RCRA-empty”. At that point it can be handled as any other waste metal container, generally as scrap metal under the recycling rules. Note that the can is still considered a solid waste at this point (not necessarily hazardous waste).

How do I figure out the shelf life of a product?

The shelf life of a product can be found on either the technical data sheet (TDS), available on the product page, or by looking on the certificate on conformance (COC). The COC can be downloaded by going to https://www.chemtronics.com/coc. Once you have the shelf life, you will need to add it to the manufacture date for a use-by date. The manufacture date can be identified by the batch number. The batch code used on most of our products are manufacture dates in the Julian Date format. The format is YYDDD, where YY = year, DDD = day. For example, 19200 translates to the 200th day of 2019, or July 19, 2019. This webpage explains and provides charts to help interpret our batch numbers: https://www.chemtronics.com/batch-codes.

How do you prevent the valve from clogging up when using aerosol conformal coating?

I suggest you get into the habit of clearing the valve after every use. You turn the can upside-down and spray until it only sprays propellant. If you don’t do that, you run the risk of dried coating building up in the valve or actuator button. If in the button, you can switch it for another one and it should work. If in the valve, there may not be much you can do to save the can.

Articles

HOW-TO: Conformal Coating Application Using Aerosol Spray

HOW-TO: Conformal Coating Application Using Aerosol Spray

Step-by-step instructions on how to properly apply aerosol coatings without common defects.
Read This Post
Webinar: Optimizing Selective Spray Conformal Coating for Maximum Output

Webinar: Optimizing Selective Spray Conformal Coating for Maximum Output

This is a overview of PCBA conformal coating application with selective spray systems and tips for optimizing equipment settings and chemistry selection for the best (and most profitable) possible performance. Presented by industry experts Pierce Pillon, Senior Field Engineer of Techspray, and Jon U...
Read This Post
Conformal Coating Defects: When Things Go Horribly Wrong

Conformal Coating Defects: When Things Go Horribly Wrong

Even small failures can cause conformal coating defects and your line to shut down. This video shows how to diagnose, solve, and prevent defects in your process
Read This Post
The Ultimate Guide to Conformal Coating

The Ultimate Guide to Conformal Coating

Conformal coating is engineered to protect circuit boards, components, and other electronic devices from moisture, thermal shock, static, vibration, and contamination. These coatings ‘conform’ to the irregular landscape of the PCB providing increased dielectric resistance, operational integrity, and...
Read This Post
How To Evaluate The Best Silicone Conformal Coating

How To Evaluate The Best Silicone Conformal Coating

Many engineers specify legacy silicone coatings as a “good enough” de facto standard, but shortages in those product lines open the opportunity to consider other materials with superior characteristics. Unfortunately, evaluating new coatings and potentially having to adjust processes to accommodate ...
Read This Post
8 Essential Tips for Conformal Coating Dip Application

8 Essential Tips for Conformal Coating Dip Application

If you are wondering on how to apply your conformal coating or considering the different options for your conformal coating process, take a look at this quick post covering the best practices of dip applications for coating PCBs.
Read This Post

Related Products
You did not finish submitting your information to request a sample